Installation Procedure

Installation of indoor unit

Installation for air duct of indoor unit 1. Installation for air supply duct

This type of unit uses circular air duct with its caliber of 180mm.

An additional transitive air duct is necessary for the circular air duct to connect to the air supply inlet. It should be also connected to its respective air diffuser separately. See Fig.1. Adjust the wind speed of each air diffuser outlet to keep in line on the whole, so as to meet a demand of the air conditioner in the room.

flexible joint

transitive air duct

Indoor unit or static pressure box

circular air duct

 

joint of air diffuser

air diffuser

Fig1: Duct connected

2. Installation for air return duct

Use rivets to connect the air return duct to the air return inlet of the indoor unit. The other end connects to the air return shutter. as shown in Fig.2.

air return

air return

 

shutter

duct

indoor unit

 

 

rivet

Fig2: Duct return connected

3. Air duct insulation

Insulation layer is needed for air supply and return duct. First, paste a glue nail to the air duct, and then attach the insulation cotton that has a tinfoil layer and use the glue nail cover to fix. Finally, seal the air duct interface with tinfoil adhesive tape closely. as shown in Fig3.

galvanized

insulating

glue nail cover

adhesive tape

board

fabric

tinfoil

 

glue nail

Fig3