5 Solving Problems

4Make sure the flow control method you selected in software matches the method selected in the modem. If you are using the modem with a Macintosh, you might have the wrong cable for hardware flow control.

If you are running under Windows 3.1 and have a 16550AFN UART, you might need to turn on the 16550’s data buffers and/or replace the Windows serial driv-

4er, COMM.DRV.

Try entering the &V1 command to display information about the last connection, making a screen print of the connection statistics, and checking for parameters that might be unacceptable.

There Are Garbage4 Characters on the Monitor

Your computer and the remote computer might be set to different word lengths, stop bits, or parities. If you have connected at 8-N-1, try changing to 7-E-1, or vice-versa, using your communications software.

You might be experiencing line noise. Enable error correction, if it is disabled, or

4hang up and call again; you might get a better connection the second time.

At speeds above 2400 bps, the remote modem might not use the same transmis- sion or error correction standards as your modem. Try connecting at a slower speed or disabling error correction. (With no error correction, however, line noise

4can cause garbage characters.)

Try entering the &V1 command to display information about the last connection, making a screen print of the connection statistics, and checking for parameters that might be unacceptable.

The Modem4Doesn’t Work with Caller ID

Caller ID information is transmitted between the first and second rings, so if autoanswer is turned off (S0=0) or if the modem is set to answer after only one ring (S0=1), the modem will not receive Caller ID information. Check your ini- tialization string, and if necessary change it to set the modem to answer after the

4second ring (S0=2).

Make sure that you have Caller ID service from your telephone company.

Fax and Data4Software Can’t Run at the Same Time

Communications devices can be accessed by only one application at a time. Un- der DOS or Windows 3.1x, you can run either your fax software or your datacomm software, but not both at the same time, unless you have a special communications device management application. In Windows 95, you can have data and fax communication applications open at the same time, but they cannot use the same modem at the same time.