Outdoor Installation

Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes.

The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.

Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear to engine and alternator parts.

CAUTION - EXHAUST HAZARD

Pay close attention to ventilation when operating the generator inside tunnels and caves. The engine exhaust contains noxious elements. Engine exhaust must be routed to a ventilated area.

Indoor Installation

Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside.The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.

Mounting

The generator must be mounted on a solid foundation (such as concrete) and set firmly on the foundation to isolate vibration of the generator when it is running. The generator must set at least 6 inches above the floor or grade level (in accordance to NFPA 110, Chapter 5-4.1). DO NOT remove the metal skids on the bottom of the generator. They are to resist damage to the bottom of the generator and to maintain alignment.

DCA-100SSVU — INSTALLATION

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

NEC articles 250-64(b) and 250-66 set the following grounding requirements:

1.Use one of the following wire types to connect the generator to earth ground.

a.Copper - 10 AWG (5.3 mm2) or larger.

b.Aluminum - 8 AWG (8.4 mm2) or larger.

2.When grounding the generator (Figure 4) connect the ground cable between the lock washer and the nut on the generator and tighten the nut fully. Connect the other end of the ground cable to earth ground.

3.NEC article 250-52(c) specifies that the earth ground rod should be buried aminimum of 8 ft. into the ground.

When connecting the generator

NOTEto any buildings electrical system ALWAYS consult with a licensed electrician.

DCA-100SSVU— OPERATION AND PARTS MANUAL — REV. #0 (11/05/07) — PAGE 17

Page 17
Image 17
Multiquip operation manual DCA-100SSVU Installation, Outdoor Installation, Indoor Installation, Mounting

DCA-100SSVU specifications

The Multiquip DCA-100SSVU is a powerful and versatile portable generator that is designed to meet the needs of a wide range of applications. Ideal for construction sites, events, and emergency power needs, this generator combines reliability with excellent performance.

One of the standout features of the DCA-100SSVU is its robust 100 kVA output, making it suitable for powering larger equipment and multiple tools simultaneously. This generator is equipped with a rugged and durable construction, ensuring it can withstand the rigors of outdoor use. Its compact design allows for easy transport and placement in tight spaces, making it an ideal choice for contractors and event planners who need a reliable power source.

The DCA-100SSVU utilizes a highly efficient diesel engine, which not only provides high performance but also ensures lower fuel consumption compared to traditional gasoline generators. This fuel efficiency translates into cost savings over time, especially for users who need extended run times. Furthermore, the generator boasts a large fuel tank capacity, allowing for longer operational periods between refuels, enhancing productivity at job sites.

In terms of technology, the DCA-100SSVU incorporates advanced sound attenuation features that significantly reduce noise levels, making it suitable for use in noise-sensitive environments such as urban areas or residential neighborhoods. Its low noise operation is not only beneficial for compliance with local regulations but also for maintaining a comfortable working environment.

The generator also comes with a user-friendly control panel, equipped with indicators for monitoring fuel levels, output voltage, and engine status, ensuring that operators can easily manage the generator's performance. This intuitive design minimizes the learning curve for new users and enhances operational efficiency.

Safety features are paramount in the DCA-100SSVU design. It includes protective circuits against overloads and short circuits, ensuring that both the generator and connected equipment remain safe during operation. Moreover, the generator is designed with ample ventilation, preventing overheating and ensuring reliable performance even in demanding conditions.

In summary, the Multiquip DCA-100SSVU is a reliable and efficient portable generator that offers impressive power output, fuel efficiency, low noise levels, and a host of user-friendly features. It is an excellent choice for professionals who require a dependable power source for various applications, making it a standout option in the generator market.