Multiquip gb43sc GLOBUG 4-SPOT -TROUBLESHOOTING LAMPS, Lamp Troubleshooting, Symptom, Solution

Models: gb43sc

1 54
Download 54 pages 18.88 Kb
Page 28
Image 28
GLOBUG 4-SPOT —TROUBLESHOOTING (LAMPS)

GLOBUG 4-SPOT —TROUBLESHOOTING (LAMPS)

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the diagnosis based on the Lamp Troubleshooting (Table 4) information shown below.

If the problem cannot be remedied, please leave the unit just as it is and consult or company's service department.

TABLE 4. LAMP TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Are couplers not securely connected?

Connect coupler correctly.

 

 

 

 

Is generator lamp switch turned off?

Turn on switch.

 

 

 

 

Is lamp loose?

Screw lamp securely into socket.

 

 

 

 

Are connectors not properly connected?

Connect disconnected contactor.

 

 

 

 

Are any other electric appliances (other

 

Lamp does not light.

than light tower) plugged into power

Unplug all other appliances.

source?

 

 

 

 

 

 

 

Is generator voltage not normal (non-load

Repair or replace generator.

 

voltage - 120 VAC)?

 

 

 

 

 

 

Is model of lamp not compatible?

Use genuine MQ lamp.

 

 

 

 

Is lamp not cool enough to light again?

 

 

(Interval of 20 to 30 minutes is required

Wait for lamp to cool down.

 

before turning on lamp again)

 

 

 

 

 

Is generator voltage not normal (non-load

Repair or replace generator.

Lamp only lights for a

voltage - 120 V)?

 

short time.

Is ambient temperature too high (more than

Move lamp where there is proper

 

 

104 °F (40 °C)?

ventilation.

 

 

 

PAGE 28 — GLOBUG 4-SPOT — OPERATION AND PARTS MANUAL — REV. #3 (12/15/08)