INSPECTION / MAINTENANCE

SGW-250SS — MAINTENANCE

 

INSPECTION / MAINTENANCE

10 Hrs DAILY

250 Hrs

500 Hrs

1000 Hrs

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

X

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

X

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

X

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter *1

 

X

 

 

 

 

 

 

 

 

 

ENGINE

 

Clean Air Filter

 

X

 

 

 

 

Drain Bottom of Fuel Tank

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

X

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter *2

 

 

X

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level

 

 

X

 

 

 

 

 

 

 

 

 

 

Replace Air Filter Element

 

 

 

X

 

 

 

 

 

 

 

 

 

Check all Hoses and Clamps

 

 

 

X

 

 

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

X

 

 

 

 

 

 

 

GENERATOR

 

Measure Insulation Resistance Over 3M ohms

 

X

 

 

 

 

 

 

 

 

 

*1 Replace engine oil and filter at 100 hours, first time only.