SGW-250SS — PREPARATION FOR LONG -TERM STORAGE

SGW-250SS — PREPARATION FOR LONG -TERM STORAGE

Welder/Generator Storage

For storage of the generating set for over 30 days, the following is required:

zDrain the fuel tank completely.

zRun the engine until the gasoline in the carburetor is completely consumed.

zCompletely drain the oil from the crankcase and refill with fresh oil.

zRemove the spark plug, pour 2 or 3 cc of SAE 30 oil into the cylinder and crank slowly to distribute the oil.

zSlowly rotate the engine a few times with the and install a new plug.

zRemove the NEGATIVE battery cable from the negative post on the battery.

zStop the engine at the compression point.

zClean all external parts of the generating set with a cloth.

zCover the generating set and store in a clean, dry place.