Multiquip operation manual SGW-250SS -WELDEROPERATING INSTRUCTIONS, Auxiliary AC Power

Models: SGW-250SS

1 92
Download 92 pages 45.39 Kb
Page 29
Image 29
SGW-250SS —WELDER OPERATING INSTRUCTIONS

SGW-250SS —WELDER OPERATING INSTRUCTIONS

CAUTION :

NEVER switch the CV/CC Selector Switch during any welding operation. When switching a selector switch, fully rotate it to the right or left position.

NOTE

When the CV/CC Selector Switch is in the CC position, the Voltage Control function is inoperative.

1.Turn the CV/CC Selector Switch (Figure 10) to the CV position, and adjust voltage using the Voltage Control knob.

3.Set the CC Current Range Selector Switch to the desired position (Low/High).

4.Adjust current output, by setting Current Control knob to desired current output.

NOTE

When using theCurrent Control knob to adjust the current output, the outer scale is for the high range, and the inner scale is for the low range.

Figure 10. Welding Voltage Adjustment

NOTE

When the CV/CC Selector Switch is in the CV position, the Current Control , and Current Range Selector Switch functions are inoperative.

2.Turn the CV/CC Selector Switch (Figure 11) to the CC position.

Auxiliary AC Power

The Auxiliary AC power in most cases will not be affected by the CV/CC Selector Switch or any controls (Figure 12) on the front panel, and will supply a stable constant AC voltage except when the welding mode is activated.

Figure 12. Auxilliary AC Power

Figure 11. Welding Current Adjustment

NOTE

When welding, remember that the output of the AC AUXILIARY POWER is affected by the welding operation. See next page for generator output voltage conditions when welding.

SGW-250SS DC WELDER/AC GENERATOR — PARTS & OPERATION MANUAL — REV. #2 (08/08/01) — PAGE 29

Page 29
Image 29
Multiquip operation manual SGW-250SS -WELDEROPERATING INSTRUCTIONS, Auxiliary AC Power