BASICA/QuickBASIC GPIB-PC Function Calls Section Four A
GPIB-PC User Manual 4A-80 ©National Instruments Corp.
Device Example:
1. Change the time limit for calls involving the device TAPE% to
approximately 300 msec.
100 V% = 10
110 CALL IBTMO (TAPE%,V%)
Board Example:
1. Change the time limit for calls directed to the interface board
BRD0% to approximately 10 msec.
100 V% = 7
110 CALL IBTMO (BRD0%,V%)