Appendix B Common Errors and Their Solutions
©National Instruments Corp. B-5 GPIB-PC User Manual
ENEB(7)Error Condition: Non-existent GPIB-PC board.
Solution:
• Run IBCONF and make sure the board type (GPIB-PCII, PCIIA
or PCIII) and base I/O address match the hardware and address
switch settings. If you make any changes, reboot after leaving
IBCONF.
EOIP(10)Error Conditions: I/O started before previous operation completed.
Solution:
• When using asynchronous reads or writes, call IBWAIT to wait
for CMPL status before making another call.
ECAP(11)Error Condition: No capability for operation.
Solution:
• Run IBCONF and verify that the capability to do a particular
call is enabled (e.g., you must be System Controller to execute
the IBSRE function). Check both device and board
capabilities. Reboot after leaving IBCONF if you made any
changes.
EFSO(12)Error Condition: File system error.
Solutions:
• Check the disk files to make sure names are properly specified
and that the file exists.
• If more room is needed on the disk, delete some files.
• Rename any files which have the same name given to a device
in IBCONF, or rename the device.