Appendix A Multiline Interface Messages©National Instruments Corp. A-5 GPIB-PC User ManualInterface Message Reference List (Continued)
Mnemonic Message Interface Function(s)
REMOTE MESSAGES RECEIVED (continued)
REN remote enable RL
RFD ready for data SH
RQS request service (via L, LE)
[SDC] selected device clear DC
SPD serial poll disable T, TE
SPE serial poll enable T, TE
SRQ service request (via C)
STB status byte (via L, LE)
TCT or [TCT] take control C
UNL unlisten L, LE
REMOTE MESSAGES SENT
ATN attention C
DAB data byte
DAC data accepted AH
DAV data valid SH
DCL device clear (via C)
END end (via T)
GET group execute trigger (via C)
GTL go to local (via C)
IDY identify C
IFC interface clear C
LLO local lockout (via C)
MLA or [MLA] my listen address (via C)
MSA or [MSA] my secondary address (via C)
MTA or [MTA] my talk address (via C)
OSA other secondary address (via C)
OTA other talk address (via C)
PCG primary command group (via C)
PPC parallel poll configure (via C)
[PPD] parallel poll disable (via C)
[PPE] parallel poll enable (via C)
PPRn parallel poll response n PP
PPU parallel poll unconfigure (via C)
REN remote enable C
RFD ready for data AH
RQS request service T, TE
[SDC] selected device clear (via C)
SPD serial poll disable (via C)
SPE serial poll enable (via C)
SRQ service request SR
STB status byte (via T, TE)
TCT take control (via C)
UNL unlisten (via C)
UNT untalk (via C)