Getting Started

PBX power is off

A valid station number is not assigned to the built-in PBX modem

Busy Signal

Action: Listen to the modem while it dials to determine that a busy signal is received. Reasons:

Incorrect phone number

PBX modem is being accessed by another user

Ring and Answer, but no connect

message

Action: Listen to the modem while it dials to determine that the PBX answered. Watch for a Connect message.

Reasons:

PC modem's highest speed is less than the PBX modem's speed

Inappropriate initialization string

Connect message, but no carrier detect

message

Action: Listen to the modem while it dials to determine that an answer was received. Watch for the Connect message, followed by the Carrier Detect message.

Reason: Possible incorrect PBX command. Do not use PBX Command 40, YY=11, Second Data = 5.

Note: If you are an advanced user, you can change any of the PBX configuration settings using the PBX Configuration dialog. This dialog is accessed from the PAM by selecting PBX Configuration from the Edit menu, then selecting Dialog View.

 