CHAPTER 16 SERIAL INTERFACE CHANNEL 0 (
µ
PD78058F SUBSERIES)
(b) Serial bus interface control register (SBIC)SBIC is set with a 1-bit or 8-bit memory manipulation instruction.
RESET input sets SBIC to 00H.
The shaded area is used in the SBI mode.Note Bits 2, 3, and 6 (RELD, CMDD and ACKD) are read-only bits.
Remarks 1. Bits 0, 1, and 4 (RELD, CMDT, and ACKT) are 0 when read after data setting.2. CSIE0: Bit 7 of Serial Operation Mode Register 0 (CSIM0)65432107
Symbol
SBIC BSYE ACKD ACKE ACKT CMDD RELD CMDT RELT
RELT Used for bus release signal output.
When RELT = 1, SO0 Iatch is set to (1). After SO0 latch setting, automatically cleared to (0).
Also cleared to 0 when CSIE0 = 0.
R/W
FF61H 00H R/W
Note
Address After Reset R/W
CMDT Used for command signal output.
When CMDT = 1, SO0 Iatch is cleared to (0). After SO0 latch clearance, automatically cleared to (0).
Also cleared to 0 when CSIE0 = 0.
R/W
RRELD Bus Release Detection
Set Conditions (RELD = 1)Clear Conditions (RELD = 0)
• When bus release signal (REL) is detected
• When transfer start instruction is executed
• If SIO0 and SVA values do not match in address
reception (only when WUP = 1)
• When CSIE0 = 0
• When RESET input is applied
RCMDD Command Detection
Clear Conditions (CMDD = 0)
• When transfer start instruction is executed
• When bus release signal (REL) is detected
• When CSIE0 = 0
• When RESET input is applied
Set Conditions (CMDD = 1)
• When command signal (CMD) is detected
Acknowledge signal is output in synchronization with the falling edge clock of SCK0 just after execution
of the instruction to be set to (1) and, after acknowledge signal output, automatically cleared to (0).
Used as ACKE=0. Also cleared to (0) upon start of serial interface transfer or when CSIE0 = 0.
R/W
ACKE Acknowledge Signal Automatic Output Control
0 Acknowledge signal automatic output disable (output with ACKT enable)
Acknowledge signal is output in synchronization with the 9th clock falling edge of
SCK0 (automatically output when ACKE = 1).
Before completion of
transfer
Acknowledge signal is output in synchronization with falling edge clock
of SCK0 just after execution of the instruction to be set to 1
(automatically output when ACKE = 1).
However, not automatically cleared to 0 after acknowledge signal output.
After completion of
transfer
1
R/W
ACKT
(Continued)