CHAPTER 19 SERIAL INTERFACE CHANNEL 2
In case of parity error
Disable the receive buffer register (RXB) from being read for a certain time (T1 + T2 in Figure 19-15) after
the reception error interrupt request (INTSER) has occurred.
Figure 19-15. Receive Buffer Register Read Disable Period
T1: Time of one data of baud rate selected by baud rate generator control register (BRGC) (1/baud rate)
T2: Time of 2 clocks of source clock (fSCK) of 5-bit counter selected by BRGC
Example of preventive measures
Here is an example of the above preventive measures.
[Condition]
fX = 5.0 MHz
Processor clock control register (PCC) = 00H
Oscillation mode select register (OSMS) = 01H
Baud rate generator control register (BRGC) = B0H (2400 bps selected as baud rate)
TCY = 0.4
µ
s (tCY = 0.2
µ
s)
T1 = 1= 416.7
µ
s
2400
T2 = 12.8 × 2 = 25.6
µ
s
T1 + T2 = 2212 (clocks)
tCY
D0 D1 D2 D6 D7 Parity
START
STOP
T1 T2
RxD (input)
INTSR
INTSER (on occurrence of
framing/overrun error)
INTSER (on occurrence of
parity error)