RS232 Interface

NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5

This function is particularly useful to determine if a lack of sound from speakers is due to failed speakers, or lack of audio signal through the VEEMUX. If no signal is seen in this display, check all connections between the audio source, the XTENDEX, and the respective Input port on the VEEMUX.

Pressing <Esc> again will return to the connections display.

RS232 Interface

A user may control the VEEMUX using an RS232 interface by connecting a PC to the 9 pin DIN male connector on the VEEMUX labeled "RS232". Using a program such as HyperTerminal or the Matrix Switcher's Control Program (page 15), the VEEMUX can be setup and controlled.

When using HyperTerminal (or a similar program), configured at the same baud rate as in the VEEMUX (default is 9,600), 8 bits, no parity, no flow control, the VEEMUX can be controlled by sending the commands in the following chart, where:

SW = the Switch Serial Address <CR> = the Carriage Return character IP = the input port

OP = the output port ip = the IP address

Command

Answer

Description

CS SW,IP,OP

*<CR>

Connect One Input (Audio/Video Source) to Output (User Port)

 

 

 

CA SW,IP

*<CR>

Connect All Outputs To Input

 

 

 

RO SW,OP

*<CR>IP<CR>

Read Connection For Output

 

 

 

CC SW,xx

*<CR>xx<CR>

Save Matrix Connections Into Memory Bank xx

xx= 00-09

 

 

RC SW,xx

*<CR>xx<CR>

Restore Matrix Connections From Memory Bank xx

Xx=00-09

 

 

CB 00,nn

none

Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)

Factory default is 9,600

 

 

RV SW,00

*<CR>string\0<CR>

Read NTI Version String

 

 

 

RU SW

*<CR>IP,OP<CR>

Read Unit Size

 

 

 

 

 

Set the IP address, ip is in xxx.xxx.xxx.xxx format,

EA SW,ip

*<CR>

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

 

 

Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

EM SW,ip

*<CR>

number of digits is minimum 1 and maximum 3 for each field.

 

 

Leading zeroes are accepted

 

 

Set the default gateway, ip is in xxx.xxx.xxx.xxx format,

EG SW,ip

*<CR>

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

 

 

Set the website timeout; timeout = numeric string of timeout in

ET SW,timeout

*<CR>

seconds.

 

 

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800

 

 

Read the IP address, ip is in xxx.xxx.xxx.xxx format,

RA SW *

<CR>ip<CR>

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

 

 

Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

RM SW *

<CR>ip<CR>

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

 

 

Read the default gateway, ip is in xxx.xxx.xxx.xxx format,

RG SW *

<CR>ip<CR>

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

 

 

Read the website timeout; timeout = numeric string of timeout in

RT SW *

<CR>timeout<CR>

seconds.

 

 

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800

If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch memory, the command will be ignored. If the SW field corresponds to the serial address, but the syntax is wrong after this field, the switch will answer with ?<CR>.