NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5

Appendix C- Distances and Resolutions for CAT5/CAT5e and CAT6 Cables

CABLE

DISTANCE (feet)

RESOLUTION

CAT5/CAT5e (UTP)

600

1024x768 at 60Hz

CAT5/CAT5e (UTP)

400

1280x1024 at 60Hz

CAT5/CAT5e (UTP)

300

1600x1200 at 60Hz

CAT5/CAT5e (UTP)

100

1920x1440 at 60Hz

CAT6 (UTP)

300

1024x768 at 60Hz

CAT6 (UTP)

200

1280x1024 at 60Hz

CAT6 (UTP)

100

1920x1440 at 60Hz

Appendix D- Product Dimensions

CONFIGURATION

SIZE (In.) WxDxH

SM-8X8-C5VA-LCD

19x12x1.75

SM-8X16-C5VA-LCD

19x12x1.75

SM-16X8-C5VA-LCD

19x12x1.75

SM-16X16-C5VA-LCD

19x12x3.5

SM-32X8-C5VA-LCD

19x12x3.5

SM-32X16-C5VA-LCD

19x12x3.5

Appendix E- Rack mounting Instructions

This NTI switch was designed to be directly mounted to a rack and includes a mounting flange to make attachment easy. Install 4 captive nuts to the rack in locations that line up with the holes (or slots) in the mounting flange on the NTI switch. Then secure the NTI switch to the rack using four 3/16" diameter screws (not provided). Each screw should be of sufficient length to go completely through the NTI mounting flange, rack frame and fully engage all threads in the captive nut. Be sure to tighten all mounting screws securely.

Do not block power supply vents in the NTI switch chassis (if provided) . Be sure to enable adequate airflow in front of and behind the NTI switch.

Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.

Rack

 

 

Captive

R NETWORK

1275 Danner Drive Tel: 330-562-7070

Nuts

TECHNOLOGIES

Aurora Ohio 44212 Fax: 330-562-1999

NTI INCORPORATED

www.nti1.com

3/16” Diameter

Screws

Figure 33- Mount Switch to a Rack

28

Page 32
Image 32