Nilfisk-Advance America SR 1100S Hood Safety Switch Operation Check, Fuse Check/Replacement/Reset

Models: SR 1100S

1 100
Download 100 pages 27.92 Kb
Page 73
Image 73
HOOD SAFETY SWITCH OPERATION CHECK

USER MANUAL

ENGLISH

HOOD SAFETY SWITCH OPERATION CHECK

1.While the engine is running, slightly open the hood (7) and check that the engine stops immediately.

If the engine keeps running when the hood (7) is open, contact an authorised Service Center or Retailer.

FUSE CHECK/REPLACEMENT/RESET

1.Drive the machine on a level ground and engage the parking brake with the pedal (3) and the lever (4).

2.Turn the ignition key (82) to "0".

3.Open the hood (7).

4.Disconnect the battery negative connector (43).

Lamellar fuse check/replacement

5.Remove the fuse box cover (46).

6.Check/replace the relevant fuse among the following (Fig. 18):

F1: Main fuse (key circuit) (15 A)

F2: Filter shaker motor fuse (25 A)

F3: Manual vacuum system fuse (40 A) (optional)

F4: Vacuum system motor fuse (30 A)

F5: Horn and fl ashing light fuse (10 A)

F6: Working light fuse (10 A) (optional)

7.Remove the electrical component box cover (50).

8.Check/replace the following fuse (Fig. 19): FT: Drive system fuse (70 A)

9.Remove and check/replace the following fuse (63): FR: Charging system fuse (70 A)

Circuit breaker check

10.Check for deactivation of one of the following fuses, then reset it after the relevant motor has cooled down:

FA: Main broom motor circuit breaker (30 A) (47)

FB: Side broom motor circuit breaker (10 A) (48)

Assembly

11.Assemble the components in the reverse order of disassembly.

F1 F2 F3 F4 F5 F6

S311406

Figure 18

FT

S311407

Figure 19

SR 1100S P

146 2559 000(2)2007-02 A

23

Page 73
Image 73
Nilfisk-Advance America SR 1100S Hood Safety Switch Operation Check, Fuse Check/Replacement/Reset, Circuit breaker check