Table 1. NHTC/NHPC Components (cont)
Item Number | Component Name | Description |
|
|
|
17 | Cylinder Plug | Cylinder plugs are press fit on cylinder electrode pins. These color |
|
| coded connections should fit snuggly, on same color pins. Replace |
|
| if loose or frayed. |
|
|
|
18 | Low Voltage Terminal Strip | The low voltage terminal strip is the location at which all controls are |
|
| connected. See Installation for details. |
|
|
|
19 | Driver Board | The driver board(s) is the housing of all fuses and relays. It is |
|
| connected to the total controller, and monitor and activate all |
|
| humidifier states. |
|
|
|
20 | Contactor | The contactor(s) when energized allow main power to energize the |
|
| cylinder electrodes, allowing current to pass, boiling the water. |
|
|
|
21 | NORTEC OnLine Module | NORTEC ONLINE OPTION NHTC ONLY. This module allows the |
| (Optional) | NHTC to be connected to the internet and communicate information |
|
| to NORTEC via the internet. See NORTEC OnLine operation for |
|
| details. NHTC only |
|
|
|
22 | Links Module | NORTEC LINKS OPTION NHTC ONLY This module allows the |
| (Optional) | NHTC to communicate with a BMS system using the |
|
| communication protocol requested at order. See NORTEC Links |
|
| operation for details. NHTC only |
|
|
|
23 | Network Terminal Strip | The network terminal strip allows up to 13 NHTC units to be |
|
| connected on one Links module and eight OnLine modules. See |
|
| Installation of NORTEC Links and OnLine for details on wiring |
|
| humidifier networks. |
|
|
|
24 | Fuse Holder | OPTIONAL FUSE PACKAGE provides protection of individual high |
|
| voltage lines in the humidifier and does not replace fuse and |
|
| external disconnect. |
|
|
|
25 | High Voltage Terminal Strip | Connection point of main power lines to the humidifier from the |
|
| underside of the strip. It is accompanied by a ground terminal which |
|
| grounds the cabinet. |
|
|
|
26 | Total Controller | The total controller board (hidden in this view) is part of the |
|
| graphical display. It is the microcomputer that sends and collects |
|
| information from the driver boards, network modules and any other |
|
| humidifier connected to it. |
|
|
|