Table 4. Status Messages with LED State
NHTC Display Message | LED state | System Action |
|
|
|
|
|
Idle | None | Unit is made idle. |
|
|
|
|
|
Humidifying | GRN (after steam | The unit has closed the contactor and is sending |
|
| production starts) | current to the cylinder to humidify. |
|
|
|
|
|
MANUAL DRAIN: ON | YEL (blink) | The drain valve is activated. |
|
|
|
|
|
SAFETY LOOP; OPEN | GRN | Steam production stopped. |
|
| (blink) |
|
|
|
|
|
|
LEVEL SENSOR; ON | None | Deactivates the fill valve to prevent overfilling. |
|
|
|
|
|
KEEP WARM ACTIVATED | None | Keep Warm feature activated, it has closed the |
|
|
| contactor to warm the water. |
|
|
|
|
|
W19: Cylinder spent | YEL, GRN | The electronics allow the cylinder to be reset up |
|
|
| to four times before locking out the humidifier. |
|
|
|
|
|
E19: Cylinder spent | YEL, RED | Humidifier interrupts operation and the fault relay |
|
|
| is activated. |
|
|
|
|
|
FOAM: FULL TANK FLUSHING | None | The unit will initiate a flush of the cylinder and |
|
|
| resume operation. |
|
|
|
|
|