Nortel Networks 2750 manual Power cord must meet the requirements described in Table

Models: 2750

1 108
Download 108 pages 23.09 Kb
Page 38
Image 38

38Chapter 2 Cabling the VPN Router and turning the power on

The power cord must meet the requirements described in Table 3.

Table 3 Power cord requirements

Requirement

Description

 

 

Current rating

The power cord must be rated for the available AC voltage

 

and must have a current rating that is at least 125 percent of

 

the gateway’s current rating (5 A @ 100 VAC or 3 A @ 240

 

VAC).

Certification

The power cord must have certification marks from an

 

acceptable regional agency.

Cord length and flexibility

The power cord must be less than 4.5 meters (14.7 feet) long.

 

It must be a flexible HAR (harmonized) cord or VDE-certified

 

cordage to comply with the gateway’s safety certifications.

Power supply connector

The connector that you plug into the AC receptacle on the

 

gateway must be an IEC 320, Sheet C13 female.

Wall outlet connector

The power cord must terminate in a male plug with

 

appropriate grounding.

To connect the power cord and turn on the system power:

1Connect the power cord to the AC receptacle on the back of the gateway (see Figure 7 on page 37).

2Connect the power cord to the power outlet.

Caution: Risk of equipment damage

Protect the VPN Router 2750 by plugging it into a surge suppressor.

3Press and release the power switch on the rear of the VPN Router 2750 (Figure 7 on page 37), and wait for the gateway to boot.

NN46110-318 02.01

Page 38
Image 38
Nortel Networks 2750 manual Power cord must meet the requirements described in Table, Power cord requirements