Norton Abrasives C6120, C3120 Phone, Monarch Hydraulic Pump Symptom /Cause, Motor Fails To Start

Models: C6120

1 90
Download 90 pages 19.25 Kb
Page 43
Image 43

7.For warranty and service information on Monarch Hydraulic pumps, contact Monarch Hydraulics at:

Phone: 616-458-1306

Web Site: http://www.monarchhyd.com/

The Norton Company does not warranty the Hydraulic Pump. If any warranty or service of the Hydraulic Pump is required contact your nearest Monarch Hydraulics service center @ (616) 458-1306, or from the Internet: http://www.monarchhyd.com/

8.Monarch Hydraulic Pump Symptom /Cause

Symptom

Cause

Motor Fails To Start

Motor Start Solenoid Switch

 

Electrical Switch "Open" Circuit Motor

Load Fails To Hold

Check Valve-Main (Poppet Type)

 

D.R. Lowering Valve (two-way, Two Position)

 

Manual Override

Load Drops Slow

D.R. Lowering Valve (two-way, Two Position)

 

System Filter

Motor Runs But Load Fails To Raise

D.R. Lowering Valve (two-way, Two Position)

 

Manual Override

 

"Ground Fault'

 

Relief Valve

 

Suction Filter

 

Pump Losing Prime (Low Or No Oil In Pump)

 

Cylinder - Piston Type

 

Worn Pump

Motor Runs Slow And Sluggish

Low Voltage

 

Motor

 

Relief Valve

Load Fails To Lower

D.R. Lowering Valve (two-way, Two Position)

 

System Filter

 

Electrical Switch

 

"Open" Circuit

9. Monarch Hydraulic Pump Test Equipment a. Pressure Group:

A small 0 5000 PSI pressure gauge, preferably glycerin filled, is a very valuable and relatively inexpensive tool for checking pressure in the various sections of the circuit.

b. DC Test Light:

A test light is simply a light bulb which has one end connected by a wire to an alligator clip and the other end connected to a metal probe. It is used to check the electrical circuit when the battery is connected to the system. The alligator clip is grounded and the light glows when

43