Appendix A

 

 

 

 

Technical Specifications

 

 

 

 

 

 

 

 

 

 

 

Table 7: SMART-AG Cable Pinouts

 

 

 

 

 

 

 

 

 

 

 

 

 

Colour

Signal Name

J1

J2

J3

 

Label

 

 

 

 

 

 

 

 

 

 

 

Red

COM1_TXD

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

COM1_RXD

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

COM2_TXD

3

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

White

COM2_RXD

4

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

COM1 GND

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

COM2 GND

5

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

White-Black

MKI GND

5

 

 

 

MKI GND

 

 

 

 

 

 

 

 

 

 

 

White-Black

ER GND

5

 

 

 

ER GND

 

 

 

 

 

 

 

 

 

 

 

White-Black

PPS GND

5

 

 

 

PULSE PER

 

 

 

 

 

 

 

 

SECOND

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

Yellow

CANI+

6

 

 

 

CANI +

 

 

 

 

 

 

 

 

 

 

 

Green

CANI-

7

 

 

 

CANI -

 

 

 

 

 

 

 

 

 

 

 

-

RESERVED

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

PWR RET (GND)

9

 

 

 

BATT -

 

 

 

 

 

 

 

 

 

 

 

Blue

EMULATED

10

 

 

 

ER_OUT

 

 

 

RADAR OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

EVENT MARK IN

11

 

 

 

MKI

 

 

 

 

 

 

 

 

 

 

 

Orange

PPS

12

 

 

 

PPS

 

 

 

 

 

 

 

 

 

 

 

-

RESERVED

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

PWR INPUT

14

 

 

 

BATT +

 

 

 

 

 

 

 

 

 

 

A.2.2 SMART-AG Connector and Cable Requirements

Custom cables for installing your SMART-AG can be created using he following guidelines:

Wire size: must be 0.5 mm-1.25 mm (20-16 AWG)

Batt + connection must be protected by 5A fast blow fuse