External Fuse Required:

Time-Delay, UL 248-14 listed:

 

100 mA/250 V

 

400 mA/250 V (Low Voltage/Power Option)

 

Time-Lag, IEC 127-3 recognized:

 

100 mA/250 V

Environmental

400 mA/250 V (Low Voltage/Power Option)

 

Conditions:

All models: 0 to 55°C (32 to 131°F),

 

90% RH non-condensing

 

• i8DV, i8DH, i16D: 0 to 50°C (32 to 122°F) for UL only.

 

90% RH non-condensing

Protection:

NEMA 4x/Type 4x/IP65 front bezel: i16D

 

NEMA 1/Type 1 front bezel: i8, i8DH, i8DV

Dimensions

i/8 Series: 48 H x 96 W x 127 mm D (1.89 x 3.78 x 5")

 

i/16 Series: 48 H x 48 W x 127 mm D (1.89 x 1.89 x 5")

Panel Cutout:

i/8 Series: 45 H x 92 mm W (1.772" x 3.622 "), 1/8 DIN

 

i/16 Series: 45 mm (1.772") square, 1/16 DI

Software:

iConnect Configuration software; iPort COM Port Redirector;

 

iLog (Excel-based software for automatic data logging).

Firmware Upgrade:

Over Ethernet

Refer to the iSeries Manual and Quickstart for complete control functions of iSeries devices with the Embedded Ethernet Server.