5.2 Address Map

The DAQP card uses eight consecutive I/O locations within the system I/O address space. The base address of the adapter is determined during hardware configuration. The eight I/O locations are used by the DAQP card as summarized in the following table.

Table 5-4. DAQP Series Card Address Map

 

 

 

 

 

 

 

 

Address

I/O Address

Port Access

Register Description

 

 

Lines

 

 

 

 

 

 

(A3A2A1A0)

 

 

 

 

 

 

 

 

 

 

 

 

0000

base + 0

Read/Write

Data FIFO

 

 

 

 

 

 

 

 

 

0001

base + 1

Write Only

Scan List (Queue)

 

 

 

 

 

 

 

 

 

 

0010

base + 2

Write

Control Register

 

 

 

 

Read

Status Register

 

 

 

 

 

 

 

 

 

 

 

Write

Digital Output Register

 

 

0011

base + 3

 

 

 

 

Read

Digital Input Register

 

 

 

 

 

 

 

 

0100

base + 4

Write Only

Pacer Clock, low byte

 

 

 

 

 

 

 

 

 

0101

base + 5

Write Only

Pacer Clock, middle byte

 

 

 

 

 

 

 

 

 

0110

base + 6

Write Only

Pacer Clock, high byte

 

 

 

 

 

 

 

 

 

0111

base + 7

Write Only

Command Register

 

 

 

 

 

 

 

 

 

1000 - 1001

base + 8, 9

Write Only

D/A port

 

 

 

 

 

 

 

 

 

1010 - 1011

base + 10, 11

Write

Timer port (re-load)

 

 

 

 

 

Read

Timer port (read latch)

 

 

 

 

 

 

 

 

 

1100 - 1110

base + 12, 13, 14

 

reserved

 

 

 

 

 

 

 

 

1111

base + 15

Write

Auxiliary Control Register

 

 

 

 

 

Read

Auxiliary Status Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The D/A and timer port can be accessed as 16 bit I/O registers and with 8 bit I/O instructions. The remaining registers are 8 bits. Each is discussed in detail in the following sections.

DAQP-208/208H/308 Users Manual

39

Page 39
Image 39
Omega DAQP-208, 208H, 308 user manual Address Map