USER menu

 

 

 

 

<TIME CODE>

 

 

 

 

Item

 

Setting

Description

No.

Superimposed

No.

Superimposed

display

display

 

 

 

 

500

VITC

0000

10L

This sets the position where the VITC signal is to be inserted.

 

POS-1

0001

11L

(The same line as for VITC POS-2 in 501 cannot be

 

 

0002

12L

selected.)

 

 

0003

13L

 

 

 

0004

14L

 

 

 

0005

15L

 

 

 

0006

16L

 

 

 

0007

17L

 

 

 

0008

18L

 

 

 

0009

19L

 

501

VITC

0010

20L

This sets the position where the VITC signal is to be inserted.

0000

10L

 

POS-2

0001

11L

(The same line as for VITC POS-1 in 500 cannot be

 

 

0002

12L

selected.)

 

 

0003

13L

 

 

 

0004

14L

 

 

 

0005

15L

 

 

 

0006

16L

 

 

 

0007

17L

 

 

 

0008

18L

 

 

 

0009

19L

 

 

 

0010

20L

 

502

VITC

0000

BLANK

This selects whether to output the VITC data to the positions

 

BLANK

0001

THRU

selected by VITC POS-1 in 500 and VITC POS-2 in 501.

 

 

 

 

0: Data is not output.

1: Data is output.

5 0 3 TCG

0000

TC&UB

REGEN

0001

TC

 

0002

UB

This selects the signal to be regenerated when the time code generator (TCG) in the REGEN mode.

0:Both the time code and user bit are regenerated.

1:Only the time code is regenerated.

2:Only the user bit is regenerated.

5 0 4 REGEN

0000

AS&IN

MODE

0001

ASSEM

 

0002

INSRT

 

0003

SW

This selects whether the time code is to be regenerated during automatic editing using the unit’s control panel.

0:Time code is regenerated with assemble or insert editing.

1:Time code is regenerated with assemble editing.

2:Time code is regenerated with insert editing.

3:Setting complies with REGEN/PRESET switch setting.

5 0 5 E X T T C

0000

LTC

SEL

0001

VITC

This selects the time code to be used when an external time code is to be used.

0:The LTC of the TIME CODE IN connector is used.

1:The video signal LITC is used.

The underline on the setting item denotes the initial setting.

- 5 2 -

Page 52
Image 52
Panasonic AJ-D750P manual Time Code