Panasonic AW-RP555N manual Parts and their functions, TO PAN/TILT HEAD 1/EXT terminal

Models: AW-RP555N

1 30
Download 30 pages 46.81 Kb
Page 13
Image 13
TO PAN/TILT HEAD 1/EXT terminal

Parts and their functions

TALLY5

 

 

TALLY3

 

 

TALLY1

 

 

TALLY2

 

DC12V IN

TALLY4

 

TALLY IN TALLY GND

 

GND

 

TO PAN/TILT HEAD

MONITOR SELECT

 

 

R

S

 

 

 

 

REMOTE/SERVICE

5

4

3

2

1/EXT

TO PAN/TILT HEAD 1/EXT terminal

Functions as the pan/tilt head’s connection terminal 1 when the EXT CONTROL OUT is set to OFF on the EXTERNAL CONTROL OUT setting (see page 18). Connect a 10BASE-T straight cable (equivalent to UTP category 5) to the pan/tilt head’s IP/RP terminal.

May be extended up to a maximum of 3,280 ft. (1,000 m). Use the RS-232C/RS-422 converter and connect

to pan/tilt head’s RS-232C control terminal when connecting to the AW-PH300, AW-PH300A, AW-PH500 or AW-PH600.

Functions as the AW-DU600 dial up adapter’s connection terminal when the EXT CONTROL OUT is set to ON on the EXTERNAL CONTROL OUT setting (see page 18). Connect a 10BASE-T straight cable (equivalent to UTP category 5) to the AW-DU600’s PAN/TILT CONTROL IN terminal. May be extended up to a maximum of 3,280 ft. (1,000 m).

For more details, refer to the operating instructions of the dial up adapter AW-DU600. Use the following terms instead:

AW-RP605 AW-RP555

EXTERNAL CONTROL OUT terminal

TO PAN/TILT HEAD 1/EXT terminal

There are no software version restrictions for this unit in systems with AW-DU600.

TO PAN/TILT HEAD 2 to 5 terminal

Functions as the pan/tilt head’s connection terminals

2 to 5 when EXT CONTROL OUT is set to OFF on the EXTERNAL CONTROL OUT setting (see page 18). Connect a 10BASE-T straight cable (equivalent to UTP category 5) to the pan/tilt head’s IP/RP terminal.

May be extended up to a maximum of 3,280 ft. (1,000 m). Use the RS-232C/RS-422 converter and connect

to pan/tilt head’s RS-232C control terminal when connecting to the AW-PH300, AW-PH300A, AW-PH500 or AW-PH600.

Cannot be used when the EXT CONTROL OUT is set to ON on the EXTERNAL CONTROL OUT setting (see page 18).

MONITOR SELECT terminal

Connect a 10BASE-T straight cable (equivalent to UTP category 5) to the AW-RC400 cable compensation unit’s MONI SEL IN terminal. May be extended up to a maximum of 164 ft. (50 m).

The video signal from the pan/tilt head system connected to the input terminal, whose number is selected on this unit, will be sent from the AW-RC400’s MONITOR 1, 2 terminals.