8.1.13. Delay OFF Timer Control

Delay OFF timer can be set using remote control, the unit with timer set will stop operate at set time.

8.1.14. Auto Restart Control

1.When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power supply resumes.

2.This type of control is not applicable during ON/OFF Timer setting.

8.1.15. Indication Panel

LED

POWER

TIMER

QUIET

POWERFUL

ION

ALLERGEN

 

 

 

 

 

 

BUSTER

 

 

 

 

 

 

 

Color

Green

Orange

Orange

Orange

Green

Blue

Light ON

Operation ON

Timer Setting ON

Quiet Mode ON

Powerful Mode ON

Ion Mode ON

Operation ON

 

 

 

 

 

 

 

Light OFF

Operation OFF

Timer Setting OFF

Quiet Mode OFF

Powerful Mode OFF

Ion Mode OFF

Operation OFF

Note:

If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode judgment, or delay ON timer sampling.

If Timer LED is blinking, there is an abnormality operation occurs.

If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.

8.1.16. Auto Operation Switch