Panasonic KX-HCM230 Interfacing to the External I/O, Explanation of External I/O, Pin Function

Models: KX-HCM230

1 128
Download 128 pages 56.99 Kb
Page 101
Image 101

Operating Instructions

4.2Interfacing to the External I/O

The Alarm mode in the Image Transfer feature requires the external sensors/ devices to be connected to the External Sensor Input of the External I/O. Certain features of this Network Camera can be activated by an external sensor that senses physical changes in the area Network Camera is monitoring. These changes can include motion detection or a physical change in the monitored area. The external sensor can also be a door switch or an infrared motion detector. These devices are customer provided, and are available from dealers who carry surveillance and security products. Electrically, they must be able to provide a momentary contact closure.

 

Explanation of External I/O

 

 

Pin

Function

 

 

1

GND

 

 

2

DC Power Output Terminal

 

12—16 V DC

 

• Maximum of 100 mA load drive is possible.

 

 

3

External Sensor Input

 

• External Sensor Input receives the signal produced by the alarm

 

sensors, (e.g., door sensor, infrared ray sensor). Those signals can

 

activate Image Transfer in the Alarm mode feature on page 68.

 

• Use it by opening or GND short-circuit.

 

 

4

External Device Control Output

 

• External Device Control Output sends the electric current to activate

 

the external devices, (e.g., light, buzzer).

 

External Output Control window can set the External Device Control

 

Output. Refer to page 83.

 

• It is an open collector circuit, and the maximum drawing-in current is

 

100 mA. Prevent the maximum voltage from exceeding DC Power

 

Output voltage of pin 2.

 

 

[For assistance, please call: 1-800-272-7033]

101

Page 101
Image 101
Panasonic KX-HCM230 Interfacing to the External I/O, Explanation of External I/O, Pin Function, External Sensor Input