Panasonic PT-D5500UL manual RS232C, Func

Models: PT-D5500UL PT-D5500U

1 68
Download 68 pages 31.51 Kb
Page 35
Image 35

RS232C

This sets the communication parameters at the serial terminals.

For details on the serial terminals, refer to “Using the serial terminals” (page 38).

IN BAUDRATE

: 9 600, 19 200 or 38 400 is

 

selected.

IN PARITY

: NONE, EVEN or ODD is

 

selected.

OUT BAUDRATE: 9 600, 19 200 or 38 400 is

 

selected.

OUT PARITY

: NONE, EVEN or ODD is

 

selected.

VPS SYSTEM

: MASTER or SLAVE is

 

selected.

GROUP

: A to Z is selected. MASTER

 

or SLAVE is also selected.

SYSTEM INFORMATION

The projector’s system information can be viewed.

SYSTEM INFORMATION

ROM VERSION

1. 00. 00

SET RUNTIME

300h

LAMP1 LOW

100h

HIGH

200h

TOTAL

300h

LAMP2 LOW

100h

HIGH

200h

TOTAL

300h

LAMP1 ON

20

LAMP2 ON

20

LAMP1 TYPE

LAD55

LAMP1 TYPE

LAD55

RETRN

FAN CONTROL1

The fan can be controlled in accordance with the operating conditions.

NORMAL : Standard setting

HIGHLAND : This is selected when using the projector at an altitude of over 1 400 meters.

FAN CONTROL2

The fan can be controlled in accordance with the direction in which the images are to be projected.

HORIZ. : Standard setting

VERTICAL : This is selected when projecting images at a significant angle toward the vertical (more than 30 degrees from the horizontal).

V

H

30 °

30 °

H

 

30 °

30 °

 

V

H: HORIZ.

V: VERTICAL

Attention • Select the correct FAN CONTROL2 setting in accordance with the direction

in which the images are to be projected. Using the projector at the wrong FAN CONTROL2 setting will shorten the service life of the lamps.

FUNC 1

The user can set the function for the remote control’s FUNC1 button.

LAMP POW : The button functions in the same way as “LAMP POWER” of “OPTION2”.

ASPECT : The button functions in the same way as “ASPECT” of “POSITION”.

AUTO POW.OFF

The projector can be automatically set to the standby mode if no signals are input for the set duration.

DISABLE : Standard setting. This function

is set to OFF.

15MIN.–60MIN.: The duration can be set in 5- minute increments from 15 to 60 minutes.

Note • The auto power OFF function does not work while the freeze function is used.

PASSWORD

This function is used when a service person. Input the password with the numeric buttons (0 to

9)of the remote control and press ENTER button to confirm the entry.

35

Page 35
Image 35
Panasonic PT-D5500UL manual RS232C, Func