Panasonic PT-D5500UL manual Error information, When Failed has appeared for an item

Models: PT-D5500UL PT-D5500U

1 68
Download 68 pages 31.51 Kb
Page 48
Image 48

Using Web Browser Control

Error information page

When is displayed on the status information screen, click it to display the error details.

OK: Normal operation

FAILED: Occurrence of trouble

Note • Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.

When [FAILED] has appeared for an item

Parameter

Description

 

 

MAIN CPU BUS

Trouble has occurred in the microcomputer circuitry. Consult your dealer.

 

 

FAN

Trouble has occurred in the fan or its drive circuit.

Consult your dealer.

 

 

 

OPTICS MODULE

The temperature inside the projector is high.

TEMPERATURE

 

 

 

INPUT AIR

The input air temperature is too high. It may be that the projector is being used

TEMPERATURE

where the ambient temperature is high such as near a heating appliance.

 

 

LAMP REMAIN TIME

The lamp runtime has exceeded the prescribed cumulative time, and it is now time

to replace the lamp.

 

 

 

LAMP STATUS

The lamp has failed to light.

 

 

OPTICS MODULE

Trouble has occurred in the temperature detection sensor inside the projector.

TEMP. SENSOR

Consult your dealer.

 

 

INPUT AIR TEMP.

Trouble has occurred in the sensor used to detect the input air temperature.

SENSOR

Consult your dealer.

 

 

BATTERY

The backup battery has been run out.

Consult your dealer.

 

 

 

COLOR WHEEL

Trouble has occurred in the color wheel or the color wheel drive circuit.

Consult your dealer.

 

 

 

If requesting service, ask your nearest Authorized Service Centre.

48

Page 48
Image 48
Panasonic PT-D5500UL manual Error information, When Failed has appeared for an item, Parameter Description