Replacing the lamp unit
WARNING!
Replacement of the lamp unit should only be carried out by a qualified technician.
Precautions on lamp unit replacement
WARNING!
When replacing the lamp, allow it to cool for at least one hour before handling it.
Remove the power plug and confirm that the surroundings of the lamp unit have cooled off.
Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, explosion might result.
A used lamp unit may burst if it is handled violently.
For disposition of used lamps, request an industrial waste disposal contractor.
Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit. If you continue to use a lamp after the replacement time, the lamp may break.
Philips screwdriver is necessary when replacing a lamp unit. Take care not to slip your hand when using a screwdriver.
Attention • A lamp unit is an optional part. Contact the dealer.
Replacement lamp unit model No.:
Rating: 300W
Long life lamp unit model No.:
Rating: 160W
•Other lamps than specified above cannot be used. Be sure to use the specified lamp.
Timing of lamp unit replacement
The lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500 hours 1 (when lamp output is HIGH and lamp selection is DUAL). However, it may happen that the lamp becomes dead (will not light) by the time of 1 500 hours 1 depending on the characteristics of individual lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals between previous lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare bulb.
If your lamp unit is not replaced after 1 300 hours 2 (with the lamp output set at “HIGH”), power supply will be turned off automatically at the time of 1 500 hours 1, entering a standby state. After 1 500 hours 1 of initial lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is turned on again.
Indication after 1 300 hours 2 (with the lamp output set at “HIGH”)
REPLACE THE LAMP
When lamp unit used hours have reached 1 300 hours 2, lamp monitor (LAMP1 or LAMP2) light up including standby state.
Further, an
After the time of 1 500 hours 1, the
1 This time period is 4 000 hours when long life lamp units are used. 2 This time period is 3 800 hours when long life lamp units are used.