Indication of lamp monitor
This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal internal temperature. These lamps flash or light up to indicate a problem.
Turn the power off and follow the steps below.
|
|
| Lamp 2 monitor (LAMP 2) | ||
|
|
| Lamp 1 monitor (LAMP 1) | ||
|
|
| Temperature monitor (TEMP) indicator | ||
Name of monitor | Lamp | Information | Checkpoint | Remedial measure | |
lamp | indication | ||||
|
|
| |||
|
|
| • Did you turn on the | • Wait about five minutes in the | |
|
|
| power when the | current status. | |
|
| ambient temperature | • Install the unit in a location | ||
| Lighting in |
| was low | having an ambient | |
| red |
| (approx. 0 °C)? | temperature from 0 to 40 °C. | |
| (lamp unit |
|
| • Remove the object that is | |
| ON) |
|
| ||
Temperature | High temperature | • Check if the | blocking the ventilation port. | ||
| |||||
monitor |
| • Move the projector to a | |||
| inside. (WARNING) | ventilation port is | |||
|
| temperature of 0 to 40 ˚C and | |||
|
|
| blocked. | ||
TEMP |
|
| the humidity of 20 to 80% (no | ||
|
| • Is the room air | |||
|
|
| condensation). | ||
|
|
| temperature too high? | ||
| Blinking in | High temperature | • Turn off the MAIN POWER | ||
| red | inside | • Check the air filter for | switch using the procedure on | |
| clogging. | ||||
| (2 times) | (Standby condition) | page 23 and clean the air filter | ||
|
| ||||
|
|
|
| (refer to page 42). | |
| Blinking in |
|
| • Turn off the main power supply | |
| Cooling fan has |
| (MAIN POWER) switch in the | ||
| red |
| |||
| been stopped. |
| procedure shown on page 23 | ||
| (3 times) |
| |||
|
|
| and consult the distributor. | ||
|
|
|
| ||
|
|
| • Did you notice a | • This lamp monitor lights up | |
|
|
| “REPLACE THE | when the lamp unit used hours | |
| Lighting in | Indicates the time | LAMP” message on | have reached 1 300 hours | |
| for replacing the | the screen when | (3 800 hours when long life | ||
| red | ||||
| lamp unit. | turning on the | lamp units are used). Request | ||
|
| ||||
Lamp monitor |
|
| projector power | the dealer to replace the lamp | |
|
| supply. | unit. | ||
|
|
|
•Did you turn the power • Wait until the lamp has cooled
LAMP1 LAMP2 |
|
| back on immediately | off, and then turn on the |
| |
|
|
|
| |||
|
|
| after turning it off? | power. |
| |
Blinking in |
|
|
|
|
|
|
Error is detected in | • Some error has |
|
|
| ||
red | arisen in the lamp |
| • Turn off the MAIN POWER |
| ||
the lamp circuit. |
|
| ||||
(3 times) | circuit. |
| switch using the procedure on |
| ||
|
|
|
| |||
|
|
| • Check for fluctuation |
| page 23 and consult the |
|
|
|
| (or drop) in the source |
| dealer. |
|
|
|
| voltage. |
|
|
|
Attention • To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps on pages 22, 23.
•If the main power turns off after the TEMP monitor flashes, the projector has malfunctioned. Please consult your dealer.
41