8CAM ADDRESS

Camera addresses are assigned to each of the unit's cam- era input.

1.Move the cursor to CAM ADDRESS , then press SET. The CAM ADDRESS window appears.

CAM ADDRESS

CAMERA IN

ADDRESS

1CH

 

 

 

1

 

2CH

 

 

 

2

 

3CH

 

 

 

3

 

4CH

 

 

 

4

 

2.Specify a number with the [–] or [+] button. The default setting is 1.

Available numbers: 1-99, – (no assignment)

Note: This setting takes effect only when the UNIT switch is set to 0 on the front panel.

3.Repeat the above step until all camera inputs are given addresses.

4.Press ESC to return to the communication setup.

8WAIT TIME

The unit will retransmit data when there is no response dur- ing the specified wait time.

1.Move the cursor to WAIT TIME, then specify a time with the [–] or [+] button. The default setting is OFF.

Available wait times (ms): OFF, 100, 200, 400,

1 000

8DELAY TIME

This setting specifies a delay time that the unit suspends to return the response to the received command.

1.Move the cursor to DELAY TIME, then specify a time with the [–] or [+] button. The default setting is OFF.

Available delay times (ms): OFF, 10, 20, 40, 100

8X-ON/X-OFF

1.Move the cursor to XON/XOFF, then specify a mode with [–] or [+] button. The default setting is NOT USE.

USE: Data flow control is enabled during communica- tion.

NOT USE: Disabled.

2.Press ESC to return to the WJ-MP204C SETUP MENU.

8BAUD RATE

1.Move the cursor to BAUD RATE, then specify a rate with the [–] or [+] button. The default setting is 19 200.

Available rates (bit per second): 19 200, 9 600,

4 800, 2 400

8DATA BIT

1.Move the cursor to DATA BIT, then specify a bit length with the [–] or [+] button. The default setting is 8.

Available bit length: 7, 8

8PARITY

1.Move the cursor to PARITY, then specify a check mode with the [–] or [+] button. The default setting is NONE.

Available check modes: NONE, EVEN, ODD

8STOP BIT

1.Move the cursor to STOP BIT, then specify a bit length with the [–] or [+] button. The default setting is 1.

Available bit length: 1, 2

System setup

(Camera Communication Protocol)

Parameters related to alarm, sync and remote functions are set in this menu for a Camera Communication Protocol sys- tem.

The SYSTEM menu is displayed when you select it in the WJ-MP204C SETUP MENU.

SYSTEM

ALARM MODE ON

COMP/VD2/DATA

VS/VD INPUT VD

DAISY MODE ON

TERMINAL ALARM

8Alarm mode setup

In the SYSTEM menu, move the cursor to ALARM MODE.

Select ON or OFF with the [–] or [+] button, then press SET. The default setting is ON .

ON : Opens a submenu shown below.

OFF: Alarm mode is disabled.

25

Page 25
Image 25