OPERATION
Camera selection and alarm operations are made on the front panel of the unit or
■Camera Selection
●Front Panel Operation
•You need to remove the front cover loosening the screw with a screw driver before starting operation.
•Press a camera number button.
1 | 2 | 3 | 4 |
The selected camera picture is displayed on the moni- tor connected to the SPOT OUT terminal on the rear of the unit.
■Alarm Operation
●Alarm Input
An alarm arises in the following cases.
•Terminal alarm
A sensor input is supplied to the unit telling that a change has been detected.
•Site alarm
A camera detects motion change in video (VMD, Video Motion Detection).
●Processing
•The spot image changes to that of the alarm activated camera when ALARM MODE is set to ON in the setup.
•The camera moves to the preset position.
•“ALARM ***” blinks overlaid on the spot image when ALARM DISPLAY is set to ON.
ALARM 001
• The alarm indicator blinks.
●
•Enter a camera number with numeric buttons, then press the CAM/SET button.
CAM
SET
The selected camera picture is displayed on the monitor connected to the SPOT OUT terminal on the rear of the unit.
●Alarm Output
The alarm activation is informed to the connected peripher- als via the DATA terminal or ALARM/REMOTE terminal when the terminal is set to the alarm output mode. Output duration is specified with the ALARM OUTPUT setup.
•Digital Disk Recorder enters a specific recording mode.
•Video Multiplexer changes
•System Controller makes the alarm indicator blink on the controller.
28