8Alarm input

Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector remains in the default position (CN703, ALM IN):

Pin #6 accepts CH 1 alarm input from the connected sensor. Pin #7 accepts CH 2 alarm input from the connected sensor. Pin #8 accepts CH 3 alarm input from the connected sensor. Pin #9 accepts CH 4 alarm input from the connected sensor.

8Alarm output

Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector is changed to CN702 (ALM OUT):

Pin #6 supplies CH 1 alarm output when the connected camera detects video motion (VMD) in the image. Pin #7 supplies CH 2 alarm output as above.

Pin #8 supplies CH 3 alarm output as above. Pin #9 supplies CH 4 alarm output as above.

8Spot switching input

Available when TERMINAL is set to REMOTE in the setup, and the internal connector remains in the default position (CN703, ALM IN):

Pin #6 accepts the switching signal that changes the spot output image to CH 1. Pin #7 accepts the signal to switch image to CH 2.

Pin #8 accepts the signal to switch image to CH 3. Pin #9 accepts the signal to switch image to CH 4.

8Spot switching output

Available when TERMINAL is set to REMOTE in the setup, and the internal connector is changed to CN702 (ALM OUT): Pin #6 supplies a tally output while CH 1 is selected.

Pin #7 supplies a tally output while CH 2 is selected. Pin #8 supplies a tally output while CH 3 is selected. Pin #9 supplies a tally output while CH 4 is selected.

Internal Setting

The following functions can be set with internal connectors and switches when you need to change default settings marked with *. Refer to the Service Manual for internal settings.

ALARM/REMOTE terminal definition (In*/Out) ............... CN702, CN703

Alarm reset signal input (0V-5V*/O.C) ........................................ SW704

Setup menu to CAM OUT (ON*/OFF) ......................................... SW702

RS-485 DATA Port Connection (PS Data)

Data ports are connected with RS-485 cables among devices using PS Data protocol as follows.

• Internal Diagram

RX (B) RX (A)

TX (B) TX (A)

No.

Name

Data Flow

No.

1

1

GND

 

1

Controller end

 

2

RX(B)

WJ-MP204C

WV-CU360C

2

1

 

3

RX(A)

WJ-MP204C

WV-CU360C

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

TX(B)

WJ-MP204C

WV-CU360C

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

TX(A)

WJ-MP204C

WV-CU360C

5

 

 

 

 

 

 

 

6

6

 

 

 

 

 

 

6

GND

 

6

 

 

 

 

 

 

 

17

Page 17
Image 17
Panasonic WJ-MP204C manual Internal Setting, RS-485 Data Port Connection PS Data