The ALARM MODE sub menu appears.

ALARM MODE

 

 

 

 

MONITOR SPOT

ON

ALARM DISPLAY

 

 

 

 

ON

SITE ALARM

 

 

 

 

ON

TERM.ALARM

 

 

 

ON

ALARM OUTPUT

 

 

10S

ALARM DATA

 

AUTO2

1.Move the cursor to MONITOR SPOT to select ON or OFF with the [–] or [+] button. The default setting is ON. This setting specifies whether to change the monitoring image when an alarm operates.

ON: The image displayed on the monitor screen changes to that of the alarm activated channel.

OFF: The image displayed will not change even when an alarm operates.

2.Move the cursor to ALARM DISPLAY. Select ON or OFF with the [–] or [+] button. The default setting is ON. Alarm display “ALARM ***” on the monitor is enabled or disabled while an alarm is in operation. “***” is the alarm channel number.

ON: Enabled.

OFF: Disabled.

3.Move the cursor to SITE ALARM. Select ON or OFF with the [–] or [+] button. The default setting is ON.

A site alarm (motion detection) generated by a camera is accepted or ignored.

ON: Enabled.

OFF: Disabled.

4.Move the cursor to TERM. ALARM (terminal alarm). Select ON or OFF with the [–] or [+] button. The default setting is ON.

An alarm input to the rear terminal is accepted or ignored.

ON: Enabled.

OFF: Disabled.

5.Move the cursor to ALARM OUTPUT. Select an output duration with the [–] or [+] button. The default setting is 10S (seconds).

The output status is supplied to the terminals on the rear. The output is reset along with the activated alarm according to this setup.

EXT: The output is reset when a reset input is supplied to the rear panel or the alarm reset button is pressed on the front panel.

1S-5MIN:The output is reset when the preset duration elapses.

OFF: No output.

6.Move the cursor to ALARM DATA. Select an output time with the [–] or [+] button. The default setting is AUTO2. The unit notifies the connected System Controller (must be set to Unit #1) of the alarm activation once every period preset by this setup.

POLLING: The unit issues a notification only when the controller inquires.

AUTO 1: Notification is made immediately.

AUTO 2: Notification is made once every 5 seconds.

7.Press ESC to return to the SYSTEM menu.

SYSTEM

ALARM MODE ON

COMP/VD2/DATA

VS/VD INPUT VD

DAISY MODE ON

TERMINAL ALARM

8Cable compensation/VD2 sync/data setup

The COMP/VD2/DATA menu is displayed when you select it in the SYSTEM menu.

COMP/VD2/DATA

CAMERA IN 1CH

COMP S

VD2 ON

DATA ON

In this menu, each camera is set up for cable compensa- tion, VD2 sync and data communication ON/OFF.

1.Move the cursor to CAMERA IN. Select a camera input channel with the [–] or [+] button. The default setting is 1CH.

The camera channel to be set up is selected and the image of the channel is displayed in the background of the setup menu.

Available channels: 1CH, 2CH, 3CH, 4CH