![Using Two DC Power Sources for Power Redundancy](/images/new-backgrounds/117463/11746357x1.webp)
2. Installation
Using Two DC Power Sources for Power Redundancy
Procedure
✔Make sure that the DC power source wires are not powered (that is, the circuit breakers are open).
✔The ends of the power source wires
To supply two DC power sources to the 8620 chassis for power redundancy:
1.Insert the following wires in the appropriate terminal and securely fasten each wire by tightening the screw directly above it. The insulation should be fully within the terminal block and no bare wire should be exposed outside of the block.
2.Clearly label these four power source wires as
Insert Power Source . . . | Into the . . . |
|
|
Negative side of the first power source | |
(Power Source A) |
|
|
|
(Optional) Negative side of the second | |
power source (Power Source B) |
|
|
|
Positive side of the first power source | RTN A (return) terminal. |
(Power Source A) |
|
|
|
(Optional) Positive side of the second | RTN B (return) terminal. |
power source (Power Source B) |
|
|
|
GranDSLAM 8620
RTN | ||||||
A | B | A | IP | MVL 8314 | B | |
| MVL 8314 | |||||
|
|
| IP |
| ||
|
|
| MCP | 8000 |
| |
|
|
| 10/100BT | 8025 |
| |
| RX |
|
|
|
|
|
TX |
|
|
|
|
|
|
3.Turn on power to the Hotwire 8620 GranDSLAM chassis.
4.Make sure the PWR A and PWR B LEDs on the front panel are both ON (green).