LEDs

4. Troubleshooting

LEDs

The following table describes the meaning and states of the LEDs on the front panel of the SIM card in the GranDSLAM chassis. For individual card LEDs, see the appropriate card Installation Instructions.

ALARMS

 

 

M

M

DC

 

A

I

F

J

N

POWER

A

O

O

 

A B N

R

R

ESD

SYSTEM

ATM

BUS

DSL

PORT

 

 

 

IP

MVL

8314

 

 

 

 

 

 

3

 

SYSTEM

ATM

BUS

DSL

PORT

 

 

 

IP

MVL

8314

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MCP

 

8000

1

GranDSLAM 8620

 

 

 

 

 

 

TX

RX

SCM-E3

10/100BT

8025

A

DC FUSES

-48V

RTN

ALARMS

ALARM

CLOCK

SERIAL

LAN

SIM

 

 

 

DC

 

 

 

 

 

SIM

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC INPUT

 

 

 

 

 

 

 

 

 

 

 

 

02-17239

LED

LED is . . .

Indicating . . .

 

 

 

PWR A

Green

Normal operation for Power Source A.

 

Off

Low, high, or no voltage for Power Source A.

 

 

 

PWR B

Green

Normal operation for Power Source B.

 

Off

Low, high, or no voltage for Power Source B.

 

 

 

FAN ALM

Yellow

Fans are working at less than 50% of normal output.

 

Off

Normal operation or no power to mounting.

 

 

 

Major Alarm

Yellow

Major alarm present on any of the cards in the chassis.

 

 

The card with alarm conditions will also have its Alarm

 

 

LED lit.

 

Off

No major alarms.

 

 

 

Minor Alarm

Yellow

Minor alarm present on any of the cards (or Power Alarm

 

 

problem) in the chassis.

 

 

The card with alarm conditions will also have its Alarm

 

 

LED lit.

 

Off

No minor alarms.

 

 

 

8620-A2-GN20-40

July 2003

4-3

Page 47
Image 47