Paradyne 8620 manual Grounding, Cooling and, Air Handling, Operating, Environment

Models: Hotwire 8620 GranDSLAM Installation Guide 8620

1 58
Download 58 pages 27.69 Kb
Page 56
Image 56
Grounding

B. Technical Specifications

Table B-1. Hotwire 8620 GranDSLAM Technical Specifications (2 of 2)

Specifications

Criteria*

 

 

Grounding

A ground lug is located on the right rear of the Hotwire 8620

 

GranDSLAM. It accepts 14 AWG wire.

 

A noninsulated banana jack is located at the left front of the Hotwire

 

8620 GranDSLAM providing a ground for the ESD wrist strap plug.

 

 

Cooling and

The internal fans are installed in the chassis to provide cooling.

Air Handling

A built-in feature shuts off power to the circuit cards if a chassis

 

 

overheats because of fan failure. If the temperature in the chassis

 

reaches 70°C, power to the cards in the chassis is turned off

 

automatically. Power is turned on when the temperature drops below

 

60°C.

 

 

Operating

Ambient Temperature for system: 32° to 122° F (0° to 50°C)

Environment

Ambient Temperature for chassis only: 32° to 140° F (0° to 60°C)

 

 

Relative Humidity: 15% to 99% noncondensing

 

Shock and vibration sufficient to withstand normal shipping

 

 

* Technical Specifications subject to change without notification.