Paradyne IPD4000E Connect Your Subscriber Lines, Identify the Appropriate RJ21 Connectors

Models: IPD4000E

1 17
Download 17 pages 40.81 Kb
Page 11
Image 11
1.7 Connect Your Subscriber Lines

Uplink Module

1.7 Connect Your Subscriber Lines

NOTE No configuration is necessary for the interface module(s) installed in your IPD4000E to operate at default settings. However, if you wish to run your subscriber connections at settings other than the factory defaults, Net to Net recommends configuring the interface module(s) prior to connection. Refer to the installation instructions for your particular interface module model(s) at http://www.nettonet.com/support/docs for configuration information.

The IPD4000E chassis supports ADSL, IDSL, SDSL and T1/E1 technologies. Ensure that the subscriber lines you are connecting correspond with the technology of the interface module(s) installed in your IPD4000E.

1.7.1 Identify the Appropriate RJ21 Connector(s)

Subscriber lines must be connected according to the IPD4000E slot in which the corresponding interface module was installed. Interface module slots 1-4 run from bottom to top; the corresponding RJ21 ports are directly behind each slot on the back of the chassis (1-4, bottom to top). Each interface module slot on the IPD4000E has two [2] corresponding RJ21 connectors on the back of the chassis: the RJ21 connectors on the left (A) provide the subscriber connections for interface module ports 1-24 (on most models) and the RJ21 connectors on the right (B) provide the subscriber connections for interface module ports 25-48 (on applicable models).

IPD4000E REAR VIEW

Interface Module B connectors

Interface Module A Connectors

subscriber connections for ports 25-48

subscriber connections for ports 1-24

(on applicable models)

(on most models)

IPD4000E Installation Instructions 220-0000097 rev01

Page 11 of 17

Page 11
Image 11
Paradyne IPD4000E installation instructions Connect Your Subscriber Lines, Identify the Appropriate RJ21 Connectors