Models 2603, 2621, and 2635 Getting Started Guide

6 • WAN Services

 

 

4.Enter the description for the circuit in the Description field. This is a mandatory field. Without a descrip- tion you cannot create a WAN service.

5.Click on Create a new service in the main window, select Frame relay bridged and click on the Configure button.

6.Click along the following path: Services Configuration > WAN > ‘Edit...’ Then click on Edit ‘Frame Relay Channel’. The configurable parameters are:

DLCI: Consult with your service provider for the DLCI number required.

Encapsulation type: Bridged Ether (Defines the RFC 1490 encapsulation type to be used by the channel. In some instances you may need to choose another type. Consult your service provider.)

RX Max PDU: 8192 Receive side max PDU, default 8192 (normally not changed from default)

TX Max PDU: 8192 Transmit side max PDU, default 8192(normally not changed from default)

Channel segment size. The channel segment size is used to define fragmentation of the packets based on the Frame Relay Forum IA FRF.12. If this variable is set to 0 then FRF.12 “Frame Relay Fragmentation” will be disabled, if set to any other value it will set the fragmentation size used.

Port: Defines the port that should be used to setup the Frame Relay Connection. For routed applications the port should be set to “frf”, for bridged applications the port should be set to “fr”.

Click on the Create button.

This conclude the central site configuration.

Frame Relay Routed

This application shows the configuration for two IPLink units in routed mode. If using a third party router at the Central site, review the router’s configuration for connection to a remote bridge.

PC

IP Address

192.168.100.11

Gateway

192.168.100.2

Remote

Central

IPLink Remote

IPLink Central

 

 

Frame

 

 

 

Relay

 

IP Address

WAN IP Address

WAN IP Address

IP Address

192.168.100.2

192.168.164.2

192.168.164.3

192.168.172.3

 

WAN Gateway

WAN Gateway

 

 

192.168.164.3

192.168.164.2

 

PC

IP Address

192.168.172.229

Gateway

192.168.172.3

Figure 37. Frame Relay routed application

Remote Site Configuration.

First configure the IP address of the IPLink’s Ethernet port (interface ip1) via the command line (CLI) for 192.168.100.2/24. The PC must be on the same subnet for configuring the IPLink via the web pages.

1.Bring up the web-page management system on your browser by entering the IP address of the IPLink.

WAN Service Configuration

63

Page 63
Image 63
Patton electronic 2635, 2621 manual Frame Relay Routed