Troubleshooting

LED indicators on the front panel of the EDI5000 allow you to monitor data activity and operating power. Table F provides troubleshooting information relating to the front panel indicators.

If the following instructions fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 or 1-559-292-1981 for assistance.

Note the following before calling Pelco:

Unit serial number: located on the product label.

Unit firmware version: located on the About page in the EDI5000 system configuration software.

NOTE: Do not try to repair the unit yourself. Opening it immediately voids any warranty. Leave maintenance and repairs to qualified technical personnel. Exchange the defective unit and return it for repair.

Table F. Troubleshooting the EDI5000

Problem

Meaning

Possible Causes

Suggested Remedy

 

 

 

 

Power LED (Pelco badge)

 

 

 

 

 

 

 

Not lit

Power is not being applied to

Power connection is faulty

Check power connection; if the unit is

 

the EDI5000

 

rack mounted, reseat the unit or the

 

 

 

power supply as necessary

 

 

 

 

 

 

Power supply has failed

Replace power supply

 

 

 

 

COM Port LEDs (COM 1 and COM 2)

 

 

 

 

 

 

Not lit

RS-232 data is not being sent

Data is not present on the

No action required

 

by the data port

communications port

 

 

 

 

 

 

 

Connection is faulty

Check COM port connections

 

 

 

 

 

 

Data communication cable is

Replace cable

 

 

defective

 

 

 

 

 

C2688M-C (12/08)

39

Page 39
Image 39
Pelco AD2088 manual Troubleshooting, Problem Meaning Possible Causes Suggested Remedy