18
SunTouch Pool and Spa Control System Installation and Users Guide
Schedules Menu (4/13) (Continued)
Schedule your Spa or Pool
You can set a daily start and stop time to switch the filter pump on and rotate the pool or spa valves into the
“Spa” or “Pool” position. The heater will automatically heat the spa or pool water up to the set point
temperature as set in the “Heat” menu (see page 14). If the pool has a separate jet pump or blower controlled
by AUX 1 and/or AUX 2 , these need to be scheduled separately. You can also program when to filter and
heat your pool, and switch light or auxiliary circuits on or off.
You can create schedules to automatically run equipment like pool filtration or lights. Any circuit can be set to
switch on and off on every day of the week. When a relay is switched on manually, it remains on until you
either switch it off manually, or the next time the relay is scheduled to be switched off. For example, if the
filter pump is scheduled to automatically run from 3:00 PM to 5:00 PM daily then the filter pump is switched on
manually at 9:00 PM, it will run continuously for 12 hours until the next day at 5:00 PM then switch off. The
programmed schedule will then continue from then on. Default run time for the a scheduled program is 12
hours. If you program the start and stop times the same the schedule will run for 24 hours if scheduled to run
for one day. A spa or pool program can be overridden using the Spa button (Up arrow) or set Circuit On/Off
pool filter pump to on in the Circuit On/Off menu (see page 13).
Edit an existing program
1. Press the Menu button until Schedules (menu 4) is displayed then press the Right button.
2. Press the Up/Down button to scroll through the circuits with their assigned programs.
3. Press the Right button to move to the first digit of the program number for the circuit. For example
(2/4), two is the second program of four assigned programs.
4. Press the Up/Down button to select the desired program number.
5. Press the Right button to move to the mode setting.
6. Press the Up/Down button until Edit is displayed. To edit the start and stop time for the circuit, press
the Right button to move to the Start setting.
Delete a program
1. Press the Menu button until Schedules (menu 4) is displayed then press the Right button.
2. Press the Up/Down button to scroll through the circuits with their assigned programs.
3. Press the Right button to move to the first digit of the program number for the circuit. For example
(3/4), one is the third program of four assigned programs.
4. Press the Up/Down button to select the desired program number.
5. Press the Right button to move to the mode setting. Press the Up/Down button until “Del” is
displayed.
6. Press the Right button to delete the program 1. The program counter now displays (3/4). If you
want to delete the other three programs, repeat steps 3 through 6.