55
SunTouch Pool and Spa Control System Installation and Users Guide

Installing Valve Actuators

For shared equipment systems there are two motorized valve actuators (CVA-24T, P/N 263045) included with
the SunTouch kit.
To install a valve actuator:
1. Remove the valve knob, handle and the four screws, from the valve cover (indicated with arrows).
2. Align the splines of the actuator shaft over the shaft of the valve.
3. If the actuator is not aligned with the mounting holes on the valve cover, rotate the actuator (while
still attached to the valve) until the actuator is positioned correctly over the valve.
4. Secure the actuator with the screws provided. Only use self-tapping screws when required.
5. Mount the valve handle and knob onto the actuator.
6. At the SunTouch Power Center, route the cable up through the 1” grommet and low voltage raceway
to the motherboard (see page 48).
7. Connecting of valve actuators to the SunTouch Motherboard (see page 51):
- Connect VALVE A cable plug into the IN-TAKE (suction) 3-pin socket.
- Connect VALVE B cable plug into the RETURN 3-pin socket.
Note: For more information, see Item 2 and 3 of Plumbing requirements on page 41. Excess
cable can be coiled in the SunTouch enclosure low voltage raceway. Do not coil the wire in
upper low voltage compartment.
For Solar Heating: Use VALVE C for a solar valve actuator when solar heating is being used.
Adjusting the valve position
If the valve rotates to the wrong position, adjust the switch on the back of the actuator between ON1
and ON2 positions. This will rotate the valve to the correct position. The following diagram shows the
standard plumbing and valve actuator position.
Screw
Valve actuator
Screw
Screw
OUT (Valve A - Suction) IN (Valve B - Return)
IN