Pentax N-0751M-OD installation manual 1.2m 1.2m 0.3m 0.9m 0.3m 1 0.3m 0.3m1 0.9m, For N-0751M

Models: N-0751M-OD N-0751M

1 60
Download 60 pages 58.01 Kb
Page 10
Image 10
1.2m (4')

Clearance Requirements from Vent Terminations to Building Openings

*All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC.

[ For N-0751M]

Maintain the following clearances to any opening in any building:

In-

 

• 1.2m (4') below, 1.2m (4') horizontally from,

 

or 0.3m (1') above any door, operable win-

is

 

dow, or gravity air inlet into any building.

HeaterWhen

Indoors

0.9m (3') above any forced air inlet within

 

 

 

 

3m (10').

Clearances

stalled

 

Vent

 

 

-

 

• 0.3m (1') below, 0.3m (1') horizontally from,

isIn

Cap

or 0.3m (1') above any door, operable

Heater

Venta

window, or gravity air inlet into any building.

 

 

 

 

0.9m (3') above any forced air inlet within

VentClearancesWhen

stalledOutdoorsWith

3m (10').

(Noritz vent cap)

 

 

Illustration

1.2m (4')

1.2m (4')

0.3m (1')

0.9m (3')

0.3m (1') Manual background 0.3m (1')

0.3m (1')

0.9m (3')

*For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 900mm (36").

To forced air inlets: 1.8m (6'). These clearance requirements hold true for all of the above situations: Indoor, Outdoor w/vent cap.

10

Page 10
Image 10
Pentax N-0751M-OD installation manual 1.2m 1.2m 0.3m 0.9m 0.3m 1 0.3m 0.3m1 0.9m, For N-0751M