![Connecting Quick Connect Cord](/images/new-backgrounds/51077/5107747x1.webp)
Connecting Quick Connect Cord
For Quick Connect Multi System Installation use a Quick Connect Cord (sold separately).
Caution
The wire coloring on the Quick Connect Cord will |
|
|
|
| |
not be the same as the wire coloring of the |
|
|
|
| |
connection plug inside the unit. | 1.Red | 1.Red | 1.White | 1.Red | |
* The remote controller can be connected to either | 2.Black | 2.Black | 2.Green | 2.Black | |
3.White | 3.White | 3.Red | 3.White | ||
unit A or B. | 4.Green | 4.Green | 4.Black | 4.Green | |
5.Blue | 5.Blue | 5.Blue | 5.Blue | ||
| |||||
| 6.Blue | 6.Blue | 6.Blue | 6.Blue | |
Quick Connect | A |
| B |
| |
Cord |
|
|
|
| |
|
|
| "Quick Connect Cord" tag |
Connecting the Quick Connect Cord to the two units.
1.Turn off the power.
2.Remove the front cover of the heater (4 screws).
3.Pass the Quick Connect Cord through the wiring throughway and into the unit.
4.Plug the connector on the Quick Connect Cord to the receptacle inside the unit.
5.Attach the ground wire of the Quick Connect Cord to the terminal block fixing plate.
(If the ground wire is not attached, electrical noise may cause problems).
6.Secure the Quick Connect Cord with a clamp.
7.Replace the front cover.
Connector
Ground wire
Connector
Clamp
Wiring Throughway | Coupling Cord |
24