Connecting Remote Controller Cord to Unit
•Keep the remote controller cord away from the freeze prevention heaters in the unit.
•Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment.
•The remote controller cord can be extended up to 90m (300') with 18AWG wire.
•Use a Y type terminal with a resin sleeve. (Without the sleeve, the copper wire may corrode and cause problems).
•Be sure to hand tighten when screwing to the terminal block. Power tools may cause damage to the terminal block.
Remote controller cord
•For extensions, a 7.8m (26') cord can be purchased (Part #
•Install according to the National Electrical Code and all applicable local codes.
1.Leave enough slack so that the remote controller cord will not be damaged if the unit is removed from the wall.
2.Remove the front cover of the heater (4 screws).
3.Pass the remote controller cord through the wiring throughway and into the unit.
4.Connect the Y terminals at the end of the remote controller cord to the terminal block.
5.Secure the remote controller cord with a clamp.
6.Replace the front cover.
Terminal
Block
| Clamp |
Wiring | 18AWG Wire |
Throughways |
22