[ For N-0751M- OD]
Maintain the following clearances to any opening in any building:
Illustration
|
| • 0.3m (1') below, 0.3m (1') horizontally from, | |
Openingto ClearancesOutdoor |
| or 0.3m (1') above any door, operable | |
| window, or gravity air inlet into any building. | ||
BuildingAny into | 0.9m (3') above any forced air inlet within | ||
3m (10'). | |||
| |||
|
| • 0.3m (1') below, 0.3m (1') horizontally from, | |
is |
| or 0.3m (1') above any door, operable | |
| window, or gravity air inlet into any building. | ||
Heater | Box | ||
0.9m (3') above any forced air inlet within | |||
3m (10'). |
0.3m (1')
0.3m (1')
0.3m (1')
0.9m (3')
VentClearancesWhen InstalledinaRecess |
(recess box installation with cover removed)
0.3m | 0.3m (1') |
(1') |
|
0.3m (1')
0.9m (3')
*For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 900mm (36").
To forced air inlets: 1.8m (6').
11