3. Quick Connect Multi System Installation
•The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord.
The Quick Connect Cord is 2m (6'). long. Install the units 50 - 450mm
System Diagram
Quick Connect | Cord | Cord | |
Cord | |||
Connector | Connector | ||
|
Typical Plumbing
| Union | |
| Quick Connect | |
| cord | |
Make this distance as short as possible. | Pressure | |
Relief | ||
* The hot water temperature will | Valve | |
become unstable as the pipe | Shutoff | |
length increases. | ||
Valve | ||
|
*When connecting two units, use only a single remote controller.
Terminal Block
Remote Controller | Note: Connect the remote |
| controller to only one |
| of the units. |
Remote Controller Cord | Gas Supply Piping |
| |
G | Cold Water Supply |
| Hot Water |
Distance at center 400 - 800mm
Distance on sides 50 - 450mm
Union |
|
Union |
|
Gas Valve | Shutoff |
Shutoff Valve | Valve |
| |
| Hot Water |
| Cold Water |
Leave enough clearance around the plumbing to | Size the piping to allow for the maximum |
apply insulation. It will be necessary to add | flow rates of the units. |
bends to the piping to ensure that this clearance |
|
is available. |
|
•Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the cold water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold temperatures.
3