DANGER
Checkup [For indoor installation only]
• Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
Check the Gas
WARNING
• Check that the rating plate indicates the |
|
|
|
|
|
|
| ||
|
|
|
|
|
| ||||
correct type of gas. |
|
| Natural Gaz Naturel |
|
|
|
| ||
|
| 12,000 BTU |
|
|
|
| |||
|
|
|
| 199,900 BTU |
|
|
|
| |
• Check that the gas supply line is sized for |
|
| 202 | 765 |
|
| |||
|
| 0.65 | 2.55" |
|
| ||||
|
|
|
| 4.0 | 10.5" |
|
| ||
199,900 Btuh for this unit. |
|
|
|
|
|
|
|
| |
| 0 - 2,000 Ft. (0 - 610 m) 2,000 - 4,500 Ft.* (610 - 1,370 m*) |
| |||||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 199,900 |
| 192,800 |
|
|
Check the Power |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 168,000 |
| 162,800 |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
• The power supply required is 120V AC, at 60Hz. |
|
|
| 2.0 |
| 2.0 |
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||
Using the incorrect voltage may result in fire or electric shock. |
|
|
|
|
Use Extreme Caution if Using With a Solar
•Using this unit with a solar
CAUTION
Do Not Use Equipment for Purposes Other Than Those Specified
•Do not use for other than increasing the temperature of the water supply, as unexpected accidents may occur as a result.
Check Water Supply Quality
•If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in order to ensure full warranty coverage.