set password XXXX
Set password of the
and no longer than 7 characters.
set debug X
Set open debugging message output grade for special tool. X is ranged from 0 through 5: 0: close debugging output; 1: output the operation information to the window; 2: output all the bug information and data in test window; 3: save the bug information into SDRAM; 4: disable checks the mark.
set upgradeaddr XXX.XXX.XXX.XXX
Set IP address or domain name of FTP server supplying upgraded program of
set ntsip XXX.XXX.XXX.XXX
Set IP address of time server.
set daylight X
Set use daylight or not. X ranged from 0 through 1: 0: do not use daylight;
1: use daylight.
set timezone XX
Set time zone.
Command store
Syntax description: no keyword. Parameter ranged from 0 through 4.
Usage: Save the current settings to the designated position.
Relevant Usage: store 1
Command load
Syntax description: no keyword. Parameter ranged from 0 through 4.